<wbr id="0p4dr"><legend id="0p4dr"></legend></wbr>
  • <wbr id="0p4dr"></wbr>

  • <sub id="0p4dr"><listing id="0p4dr"></listing></sub>
    <form id="0p4dr"><span id="0p4dr"><track id="0p4dr"></track></span></form>

    <sub id="0p4dr"></sub>
    <form id="0p4dr"></form>
    1. 供應AVALCO MH311015
      供應AVALCO MH311015
      產品價格:¥1(人民幣)
    2. 規格:供應AVALCO MH311015
    3. 發貨地:廈門
    4. 品牌:
    5. 最小起訂量:1個
    6. 誠信商家
      會員級別:鉆石會員
      認證類型:企業認證
      企業證件:通過認證

      商鋪名稱:廈門紀揚科技有限公司

      聯系人:李經理(先生)

      聯系手機:

      固定電話:

      企業郵箱:624232572@qq.com

      聯系地址:福建廈門市鼓巖路1號華論國際大廈1003

      郵編:

      聯系我時,請說是在焊材網上看到的,謝謝!

      商品詳情
        Spotface
        1.399±0.002
        1 5/16-12UN- 2B IN.
        SAE-16 PORT
        0.03 0.13 0.75
        Min. Full Thread
        20°
        45°
        2.400
        2.710±0.002
        ?0.75
        INLET
        INLET P ORT BETWEEN
        80-2.00 FROM TOP
        Cavity Dimensions
        (BC20-S3)
        inch
        Housing/Element
        Flow Data
        Flow versus pressure drop:
        150 SUS (32 cSt) oil with
        specific gravity of < 0.9
        ECF - Pressure Filters
        Flows to 19 L/min (5 USgpm) ? Pressures to 207 bar (3000 psi)
        0
        4
        8
        12
        16
        20
        0 1 2 3 4 5 6
        0
        0,25
        0,50
        0,75
        1,00
        1,25
        1,50
        0 4 8 12 16 20 24
        Pressure drop - PSID
        Pressure drop -bar
        Flow Rate - L/min
        Flow Rate - USgpm
        ECF-15 
        J
        J-50.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        Orifice diameter
         ± 0,025 (0.001)
        A
        B
        C
        To abut port 1 of cartridge
         D
         E
        120
         F
        120
        D
        ?A
        B
         C± 0,025
        (0.001)
        Blank Orifice Discs
        (Conical)
         Max
         Pressure
        Cavity Drop Bar Assy
        Sizes (psi) ?A ?B ?C d E F Number
        C-8-2/4 210 (3000) 3,96 (0.156) 5,84 (0.230) 12,45 (0.490) 1,90 (0.075) 3,05 (0.120) – 02–174854
        C-8-3 210 (3000) 3,96 (0.156) 5,84 (0.230) 14,05 (0.553) 1,90 (0.075) 3,05 (0.120) – 02–178181
        C-10-2 210 (3000) 5,54 (0.218) 6,35 (0.250) 15,80 (0.622) 1,14 (0.045) 3,56 (0.140) – 566478
         15,75 (0.620)
        C-12-2 210 (3000) 7,14 (0.281) – 23,70 (0.933) 2,41 (0.095) 3,56 (0.140) 1,14 (0.045) 02-182842
         23,65 (0.931)
         Max
         Pressure
        Cavity Drop Bar Assy
        Sizes (psi) ?A B ?C Number
        C-8-2/4 13,8 (200) 12,45 (0.490) 1,27 (0.050) * 02–163254
        C-10-2/3/4 13,8 (200) 5,80 (0.622) 15,75 (0.620) 1,52 (0.060) * 02–162850
        C-16-2 13,8 (200) 28,58 (1.125) 28,52 (1.123) 2,03 (0.08) * 566247
        C-16-3 13,8 (200) 26,97 (1.062) 26,92 (1.060) 2,03 (0.08) * 02-162872
        C-16-3S/4 13,8 (200) 25,4 (1.00) 25,35 (0.998) 2,03 (0.08) * 02-174504
        *User to specify
        Blank Orifice Discs (Flat) Blank Orifice Discs (Flat)
        An orifice disc is installed
        at the bottom of a standard
        cavity to create a local
        pressure drop in the flow
        to and from port 1 of the
        cartridge.
        Blank Orifice Discs (Flat)
        Two series of discs are
        available according to the
        maximum pressure drop
        required:
        Blank Orifice Discs (Flat)
        1. Flat discs/maximum
        pressure drop/13,8 bar (200
        psi).
        2. Conical discs/maximum
        pressure drop/210 bar
        (3000 psi).
        Orifice Discs
        Note
        For predrilled orifice discs,
        consult factory.
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-51.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        10 20 50 75100 150 200 300 400 500 600 7008009001000 1500 2000 2500 3000
        dP - (psi)
        95
        98
        102
        106
        4
        0
        Flow - L/min
        114
        110
        91
        87
        83
        79
        76
        72
        68
        64
        61
        57
        53
        49
        45
        42
        38
        34
        30
        26
        23
        19
        15
        11
        8
        25
        26
        27
        28
        1
        0
        Flow - USgpm
        30
        29
        24
        23
        22
        21
        20
        19
        18
        17
        16
        15
        14
        13
        12
        11
        10
        9
        8
        7
        6
        5
        4
        3
        2
        0.7
        1.4
        3.4
        5.2
        6.9
        10.3
        13.8
        20.7
        27.6
        34.5
        41.4
        48.3
        55.2
        62.1
        69.0
        103.4
        137.9 172.4 206.9
        dP - (bar)
        15.4
        8.2
        7.7
        7.2
        6.8
        6.6
        6.4
        6.1
        5.9
        5.6
        5.4
        5.1
        4.9
        4.6
        4.4
        4.1
        3.8
        3.6
        3.3
        3.0
        2.8
        2.5
        2.3
        2.0
        1.8
        1.5
        1.3
        1.0
        .75
        .50
        .35
        12.
        8
        10.2
        8.9
        Select required orifice
        diameter using the
        graph below
        Orifice Disc - Sizing Guide (mm)
        Notes
        This chart is calculated at 21.8
        cSt and 49°C for ISO VG32 fluid
        (DTE-24), values will change
        with viscosity changes.
        Note
        To calculate orifice diameter at
        other flows and differential pressures
        use the following formula:
        D=1.350 x √(Q/(√?P)
        Note
        where D= orifice diameter in
        inches; Q= flow in US gallons
        per minute; ?P= differential
        pressure across orifice in bar.
        J
        J-52.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. .600
        .500
        .400
        .350
        .320
        .300
        .280
        .270
        .260
        .250
        .240
        .230
        .220
        .210
        .200
        .190
        .180
        .170
        .160
        .150
        .140
        .130
        .120
        .110
        .100
        .090
        .080
        .070
        .060
        .050
        .040
        .030
        .020
        .010
        95
        98
        102
        106
        4
        0
        0.7
        10
        1.4
        20
        3.4
        50
        5.2
        75
        6.9
        100
        10.3
        150
        13.8
        200
        20.7
        300
        27.6
        400
        34.5
        500
        41.4
        600
        48.3
        700
        55.2
        800
        62.1
        900
        69.0
        1000
        103.4
        1500
        137.9
        2000
        172.4
        2500
        206.9
        3000
        dP - (psi)
        Flow - L/min
        114
        110
        91
        87
        83
        79
        76
        72
        68
        64
        61
        57
        53
        49
        45
        42
        38
        34
        30
        26
        23
        19
        15
        11
        8
        25
        26
        27
        28
        1
        Flow - USgpm
        30
        29
        24
        23
        22
        21
        20
        19
        18
        17
        16
        15
        14
        13
        12
        11
        10
        9
        8
        7
        6
        5
        4
        3
        2
        dP - (bar)
        0
        Select required orifice
        diameter using the
        graph below
        Notes
        This chart is calculated at 105
        SUS and 120°F for ISO VG32
        fluid (DTE-24), values will
        change with viscosity changes.
        Note
        To calculate orifice diameter at
        other flows and differential pressures
        use the following formula:
        D=0.203 x √(Q/(√?P)
        Note
        where D= orifice diameter in
        inches; Q= flow in US gallons
        per minute; ?P= differential
        pressure across orifice in PSI.
        Orifice Disc - Sizing Guide (inches) 
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-55.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        Nominal Single or With or Required
        Cartridge Double Without Housing
        Size Acting Stops A B C Bore
        8 Single Without 15,1 (0.60) 34,1(1.34) 8,3 (0.33) 12,73 (0.500)
         Double Without 15,1 (0.60) 53,2 (2.10) 8,3 (0.33) 12,75 (0.502)
        10 Single Without 19,1 (0.75) 41,3 (1.63) 13,5 (0.53) 15,88 (0.625)
         Double Without 19,1 (0.75) 57,2 (2.25) 10,3 (0.41) 15,88 (0.625)
         Single With 19,1 (0.75) 45,7 (1.80) 6,7 (0 26) 15,90 (0.626)
         Double With 19,1 (0.75) 54,8 (2.16) 6,7 (0 26) 15,90 (0.626)
        12 Single Without 17,5 (0.69) 44,5 (1.75) 14,3 (0.56) 23,80 (0.937)
         Double Without 17,5 (0.69) 71,4 (2.81) 14,3 (0.56) 23,85 (0.939)
        16 Single Without 31,8 (1.25) 63,5 (2.50) 12,7 (0.50) 28,58 (1.125)
         Double Without 31,8 (1.25) 95.3 (3.75) 12,7 (0.50) 28,60 (1.126)
        20 Single Without 38,1 (1.50) 77,8 (3.06) 19,0 (0.75) 36,50 (1.437)
         Double Without 38,1 (1.50) 117,5 (4.63) 19,0 (0.75) 36,53 (1.438)
        Pilot Piston Assemblies
        Dimensions
        Nominal Single or With or Piston Piston Piston
        Cartridge Double Without With With Without
        Size Acting Stops Buna-N Seals Viton?
         Seal Seals
        8 Single Without 02-178662 02-178663 02-178653
         Double Without 02-178669 02-178670 02-178654
        10 Single Without 02-166275 566418 566417
         Double Without 566419 566420 02-166313
         Single With 566421 566422 566337
         Double With 566423 566424 566338
        12 Single Without 02-185700 02-185701 02-185699
         Double Without 02-185703 02-185704 02-185702
        16 Single Without 566425 566426 889052
         Double Without 566428 566429 566427
        20 Single Without 566431 566432 566430
         Double Without 566434 566435 566433
        Part Numbers
        WARNING
        The use of pilot pistons
        with check valve
        assemblies may increase the
        load applied to the valve poppet
        which may result is reduced
        fatigue life of the cartridge
        ?
        WARNING:
        Seals should not
        be used with check
        valves that have < 50 psi
        crack pressure
        ?
        Forms
        A
        B
        C
        Single-acting, without st op
        ψ
        A
        B
        C C
        Double-acting, without stops
        ψ
        B
        A
        C
        Single-acting, with stop
        ψ
        A
        B
        C C
        Double-acting, with stops
        ψ
        Note
        ψ Sealed models have a
        central O-ring with a back-up
        ring on both sides.
        Note
        Use with cartridges to form
        pilot operated check and
        similar functions in HIC and
        standard valve packages.
        Pilot Pistons
        J
        J-56.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        0.312-18 UNC-2B
        Tap thru 2 places
        1,1 (.04)
        Thick cut
        31,7
        (1.25)
        22,2
        (.87)
        15,8
        (.62) 6,35
        (.250)
        63,5
        (2.5) 20,4
        (1.0)
        50,8
        (2.0)
        1.010/1.105 Dia. thru
        #10-32 UNF-2B Tap thru
        9.5
        (.37)
        14,2
        (.56)
        Bulkhead
        Panel Mount
        Adapter
        Valve Retainer
        Sensing Check
        Sensing check kits can be
        built into customized manifolds
        to permit pilot control
        from two or more alternate
        sources, as example here:
        Typical section
        Panel Mount Adapter
        for 10 & 12 Series Valves
        Used for mounting an
        adjustable pressure valve
        through a bulkhead or
        panel surface.
        Part Number 02-161837
        Kit Part?Numbers Sense Check Kit Part. No.
        with Buna-N seals 566395
        with Viton? seals 02-183199
        Sensing Check Cavity
        12?
        12,37 (0.487)
        12,50 (0.492)
        9,78 (0.385)
        9,91 (0.390)
        0,8 (0.03)
        0,127 (0.005)
        0,254 (0.010)
        0.4375" – 20 UNF-2B
        ?6,45 (0.250)
        12,7 (0.50)
        45? Full thread
        60?
        19,0
        (0.75)
        17,47 (0.688)
        2,3 (0.09)
        2,7 (0.10)
        Plug
        Spring guide
        Spring
        Ball
        Pilot
        source A
        Pilot source B
        Sensing checks
        Sensing Check/Panel Mount Adapter
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-57.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        Solenoid Valve Parts
        Spare Parts
        Adjustment Kits
        Note
        When a solenoid valve is ordered
        as a cartridge only, the nut is
        included.
        Description Part Number
        Nut for standard core tube valves
        8 Series 02–170821
        10, 12, 16, 20 Series and SV9-8 565558
        10, 12, 16, 20 Series 350 bar valves 02-175698
        Coil Spacers
        Spacer for SV9-8 02-186730
        Spacer for SV9-10 02-179226
        Nut for extended core tube valves
         565559
        Nut for standard core tube valves.
        Nut for extended core tube valves.
        SPC1/DPC1/11
        Model Code Check Valve (Qty) Pilot Piston (QTY) Buna-N Seal Kit Viton? Seal Kit
        SPC1–10–P CV1–10(V)–P–0–15 (1) 566417 (1) 565803 566086
        SPC1–16–P CV1–16(V)–P–0–20 (1) 889052 (1) 565810 889609
        SPC1–20–P CV2–20(V)–P–0–15 (1) 566430 (1) 889615 889619
        DPC1–10–P CV1–10(V)–P–0–15 (2) 02–166313 (1) 565803 566086
        DPC11–12–P CV11–12(V)–P–0–15 (2) 02–185702 (1) 02-165889 02-165888
        DPC1–16–P CV1–16(V)–P–0–20 (2) 566427 (1) 565810 889609
        DPC1–20–P CV2–20(V)–P–0–15 (2) 566433 (1) 889615 889619
        MCV
        Model Code Check Valve (Qty) Relief Valve (Qty) Piston (Qty)
        MCV1-16 CV1-16-P-0-5 (1) RV3-16-S-0-35/ (1) 889052 (1)
        MCV4-16 CV1-16-P-0-5 (4) RV3-16-S-0-35/ (2) 889052 (2)
        MCV1-20 CV2-20-P-0-5 (1) RV3-16-S-0-35/ (1) 889052 (1)
        MCV2-20 CV2-20-P-0-5 (2) RV3-16-S-0-35/ (2) 889052 (2)
        MCV Series Knob Kit
        Description Part Number
        K (Knob kit): 565586
         Knob 02-162137*
         Jam nut 02-170637*
         Set screw 000805*
        S (nut) 565558
        * Supplied as part of kit 565586
        FCV11-12-S Series Knob Kit
        Description Part Number
        K (Knob kit): 565585
         Knob 02-184877
         Jam nut 02-184878
         Set screw 001016*
        * Supplied as part of kit 565585
        FCV7,FCV6,FR2, Series
        Knob Kit
        Description Part Number
        K (Knob kit) 565585
         Knob 02-165873*
         Jam nut 02-170635*
         Set screw 001016*
        * Supplied as part of kit 565585
        PFR2-16 Series Knob Kit
        Description Part Number
        K (Knob kit) 565586
         Knob 02-162137
         Jam nut 02-170637
         Set screw 000805
        NV1 8-Series
        Description Part Number
        C (Cap kit): 02-170163
         Cap 02-170163
         Nut 02-170161
        K (Knob kit) 02-171892
         Knob 02-174439
         Jam nut 02-174515
         Set screw 001016
        S Kit:
         Nut 02-170159
        Miscellaneous Parts
        .B
        J
        J-58.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        MRV2-16-K 16-
        Series Part Number
        Knob 02-162130
        Acorn nut 02-162992
        Nameplate 888967
        Pressure control,
         8-Series Part Number
        Retaining ring 02-166712
        K (Knob kit) 02-170164
         Cap 02-162806
         Nut 02-170159
        Retaining ring is required for C and S controls. When converting
        from the “S” or “C” option to the “K” option, remove retaining ring
        and nut before installing the knob kit.
        Pressure control,
        10 & 12-Series Part Number
        C (Cap) 02-170616*
        S (Nut) 565558*
        K (Knob kit) 565585
         Knob 02-165873
         Jam nut 02-170635
         Set screw 001016
        *These parts also used to service PUV3–10 models.
        Pressure control,
        16-Series Part Number
        S (Nut) 565558
        RV3 K (Knob kit) 565586
         Knob 02-162137
         Jam nut 02-170637
         Set screw 000805
        RV5 K (Knob Kit) 565585
         Knob 02-165873
         Jam nut 02-160635
         Set screw 001016
        RV5 C (Cap) 02–170616
        Adjustment Kits
        (cont.)
        Notes
        The only difference between the
        ‘‘D/B’’ and the ‘‘L/E’’ adjustment
        option is the orientation of the
        detent plate.
        The B/E options are not available
        in kit form. The only difference
        between these and the D/L
        versions is that the lever is
        replaced with 02-165925 and an
        additional 310204 set screw is
        required.
        NV1 10-
        Series Part Number
        Knob 888963
        Acorn nut 02-162993
        Nameplate 02-165920
        NV1 16-&20-
        Series Part Number
        Knob 02-162130
        Acorn nut 02-162992
        Nameplate(attached) 02-165922
        FAR1-10/12 & 16 Series Part Number
        Knob kit 02-185169
        MRV2-10-D/L,
        B/E 10-Series Part Number
        Lever kit: 565610
         Hub 02-169085
         Lever 888980
         Spring 888986
         Plunger 02-163705
         Insert 02-169956
         Spring 888874
         Detent pla. 02-170023
         Plate supp. 02-165090
         Nameplate 888964
         Acorn nut 02-162993
        MRV2-10-K
        10-Series Part Number
        Knob 888963
        Acorn nut 02-162993
        Nameplate 888964
        MRV2-16-D/L,
        16-Series Part Number
        Lever kit: 565611
         Hub 02-169453
         Lever 888988
         Spring 888986
         Plunger 02-163705
         Insert 02-170103
         Spring 888993
         Detent plate 02-170102
         Plate supp. 02-161901
         Nameplate 02-165922
         Acorn nut 02-162992
        Adjustment Kits (cont.)
        .B
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-59.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        Performance You Deserve
        From A Name You Trust
        When it isn’t just a question of being first ...
        But also being the best.
        As the only leading supplier
        to manufacture our hose in
        our own ISO/QS certified
        hose plants, you are assured
        the highest quality and most
        advanced hose products.
        Combining our rich heritage
        and on-track performance
        with the industry’s largest
        pool of engineering
        resources, Aeroquip
        Performance Products
        continues to prove
        There is a Difference ...
        To locate an authorized
        distributor near you, or for
        more information, visit
        www.eaton.com/
        aeroquipperformance.
        When it isn’t
        - Additional products, product lines, and services offered by Eaton -
        J
        J-70.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        1HP7 - Hand Pump
        50 bar (725 psi)
        Description
        This hand pump has been
        designed to be used on
        machines which require
        emergency release of
        brakes or for pilot supply
        for emergency lowering of
        access platforms. It can also
        be utilized in the lubrication
        circuits.
        Operation
        Depressing the plunger will
        force oil out through a check
        valve and into the system.
        The plunger will then retract
        drawing oil into the chamber
        through a second check valve.
        Features
        Built in pressure and suction
        checks. Self contained cartridge
        element. Low leakage ball and
        seat design. Minimal effort
        required for plunger movement.
        Sectional View Performance Data
        Ratings and Specifications
        Figures based on oil temperature of 40? C and viscosity of 32 cSt (150 SUS)
        Bore Diameter 9.5 mm (0.375”)
        Stroke 19 mm (0.75”)
        Displacement 1.3 cc (1.3 ml)/stroke
        Generated pressure 50 bar (725 psi)
        Cartridge material Working parts hardened & ground steel
        Body material Zinc plated steel & anodised aluminium
        Cavity Number A12370 (See Section M)
        Torque cartridge into cavity 40 Nm (30 ibs ft)
        Weight 0.16 kg (0.35 lbs.)
        Seal kit number SK1224 (Nitrile) SK1224V (Viton)
        Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal)
        Operating Temperature -30°C to +90°C (-22? to 194?F)
        Leakage 0.3 milliliters/min nominal (5 dpm)
        Nominal viscosity range 5 to 500 cSt
        2
        1
        Inlet
        Outlet
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-71.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        1HP7 - Hand Pump
        50 bar (725 psi)
         1 Basic code
        1HP7- Cartridge only
        1HP75 - Cartridge and body
        Model Code
        3 Seals
        S - Nitrile (for use with most
        industrial hydraulic oils)
        SV - Viton? (for high temperature
        & most special fl uid
        applications)
        1 2 3
        1HP7 3W S
        Dimensions
        mm (inch)
        Torque cartridge in aluminum
        housing 108-122 Nm
        (80-90 ft lbs)
        Installation Drawing
        Basic Code: 1HP75
        3/8” Ports
        Cartridge Only
        Basic Code: 1HP7
        95.0
        (3.74)
        33.0
        (1.30)
        Outlet (1)
        25.4 (1") A/F
        7/8-14 UNF-2A
        Inlet (2)
        95.00
        (3.74)
        approx
        50.80 (2.00)
        7.10
        (0.28)
        19.10
        (0.75)
        3.15 (0.12) 41.30 (1.63)
        2
        1
        38.10
        (1.50)
        18.50
        (0.73)
        50.80
        (2.00)
        31.80 (1.25)
        16.00
        (0.63)
        Code Port Size Aluminum
        Omit Cartridge only
        3W 3/8" BSP B19053
        8T 1/2" SAE B19402
        2 Port Size
        – –
        J
        J-80.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        1HP10 - Hand Pump
        250 bar (3625 psi)
        Operation
        Depressing the plunger will
        force oil out through a check
        valve and into the system.
        The plunger will then retract
        drawing oil into the chamber
        through a second check valve.
        Features
        Built in pressure and suction
        checks and inlet strainer . Self
        contained cartridge element.
        Low leakage ball and seat
        design. Minimal effort required
        for plunger movement. Handle
        rotates on body to suit user.
        Performance Data
        Description
        This hand pump has been
        designed to be used on
        machines which require emergency
        release of brakes or for
        pilot supply for emergency
        lowering of access platforms.
        It can also be utilized in the
        lubrication circuits.
        Ratings and Specifications
        Performance data is typical with fluid at 32 cST (150 SUS)
        Displacement 1.9cc/stroke
        Generated pressure 250 bar (3625 psi)
        Cartridge material Steel with hard chrome piston
        Cavity number A878 (see Section M)
        Torque cartridge into cavity 45-50 Nm
        Weight 0.8 Kg (1.76 lbs)
        Recommended Filtration Level BS5540/4 Class 18/13 (25 micron nominal)
        Operating temperature –30° to +90° C (–22° to 194° F)
        Nominal viscosity range 5 to 500 cSt
        1
        2
        .B
        J
         EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-81.A
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        1HP10 - Hand Pump
        250 bar (3625 psi)
        Dimensions in millimetres
        Tank
        Strainer
        Pump
        Flow diagram
        Inlet
        Check
        Valve
        Outlet
        Check
        Valve 55° arc of movement
        Operating handle
        Pump outlet
        25.4
        A/F HEX Pump inlet
        With integral
        Mesh strainer
        36
        38
        75
        225
        Standard cavity required:
        7/8-14 unf 2 port cavity
        Drawing upon request
        Enquiries welcomed for
        Other standard cavities
        Dimensions
        mm (inch)
        Installation Drawing
        Basic Code: 1HP15
        3/8” Ports
        Cartridge Only
        Basic Code: 1HP10
         1 Basic code
        1HP10 - Cartridge only
        1HP15 - Cartridge and body
        Model Code
        3 Seals
        S - Nitrile (for use with most
        industrial hydraulic oils)
        SV - Viton? (for high temperature
        & most special fl uid
        applications)
        1 2 3
        1HP7 3W S
        Code Port Size Aluminum
        Omit Cartridge only
        3W 3/8" BSP BXP16234
        4W ?” BSP BXP16235
        2 Port Size
        – –
        .B
        J
        J-85.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
        Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
        1T162W6S - Pressure Intensifier
        Hydraulic Integrated CIrcuits
        Description
        This valve is used to convert
        low input pressure from a
        small low pressure pump or
        sub-circuit to high pressure up
        to 700 bar (10000 psi) and can
        eliminate the need for high
        pressure pump, or high-low
        type circuit. It is best suited
        for use with low horsepower,
        variable volume pumps.
        Contact main office for full
        specifications.
        Operation
        The pressure intensifier allows
        free flow of oil through the
        inlet to the actuator until high
        pressure is required, then
        reciprocates to intensify the
        pressure with a ratio of 6.5-1
        between the inlet pressure and
        the intensified pressure up to
        a maximum 700 bar. The unit
        automatically makes up for
        any leakage to prevent loss of
        pressure during clamping or
        cutting operations. The flow to
        the ‘P’ port should be regulated
        to prevent a too rapid cycle
        rate.
        Features
        Eliminates the need for
        single stroke air/oil systems.
        Continuous automatic make up
        for leakage. Light weight and
        compact. Reliable high quality.
        Max Pressure:
        Inlet 110 bar (1600 psi)
        Output 700 bar (10,000 psi)
        Rated Flow:
        Inlet 1.5 L/min (0.4 USgpm)
        Output 165 mL/min
        (10 in3
        /min)
        Dimensions
        mm (inch)
        Torque
        cartridge in aluminum
        housing
        108-122 Nm
        (80-90 ft lbs) Installation Drawing
        Directional Control Valve
        P.O. Check
        700 bar
        High Pressure
        Clamping Cylinder
        47.7
        (1.88)
        19.0
        (0.75)
        94.0
        (3.70)
        HP
        T
        2 holes ?7.0
        (0.28) thro’
        Inlet
        47.7 (1.88)
        33.3
        (1.31)
        94.0
        (3.70)
        226.0
        (8.90
        P
        ?67.0
        (2.64)
        31.8
        (1.25)
        9.5
        (0.37)
        50.8
        (2.00)
        16.0
        (0.63)
        50.8Vickers 1RDS2522P3W12S
        Vickers 1RDS3021P10S
        Vickers 1RDS3021P10S-60BAR
        Vickers 1RDS3021P2S
        Vickers 1RDS3021P6S
        Vickers 1RDS3021P6S-15BAR
        Vickers 1RDS3022P07SV
        Vickers 1RDS3022P2S
        Vickers 1RDS3022P2S-10BAR
        Vickers 1RDS3022P6S
        Vickers 1RDS3022P6S-20BAR
        Vickers 1RDS3022P6SV
        Vickers 1RDS3022P6SV-30BAR
        Vickers 1RDS3022P8S
        Vickers 1RDS3022P8S-50BAR
        Vickers 1RDS3031P10S
        Vickers 1RDS3031P2S
        Vickers 1RDS3031P6S
        Vickers 1RDS3031P6S-20BAR
        Vickers 1RDS3032P07S
        Vickers 1RDS3032P2S
        Vickers 1RDS3032P2S-10BAR
        Vickers 1RDS3032P6S
        Vickers 1RDS3032P8S
        Vickers 1RDS3521P3W2S377
        Vickers 1RDS352-1-P3W-6S
        Vickers 1RDS3522P3W6S377
        Vickers 1RDS3531P3W2S
        Vickers 1RDS3531P3W6S
        Vickers 1RDS3531P3W6S377
        Vickers 1RDS3532P3W2S
        Vickers 1RDS3532P3W2S377
        Vickers 1RDS3532P3W6S
        Vickers 1RDS3532P3W8S
        Vickers 1RDS70211.0S
        Vickers 1RDS702-2-07S
        Vickers 1RDS70221.0S
        Vickers 1SB102S
        Vickers 1SB10S
        Vickers 1SB10S-05S
        Vickers 1SB152WS377
        Vickers 1SB153WS377
        Vickers 1SB202P12S
        Vickers 1SB202P6S
        Vickers 1SB202P6SSP-50BAR
        Vickers 1SB252P3W12S
        Vickers 1SB252P3W6S
        Vickers 1SB252P3W6S377
        Vickers 1SB304P12S
        Vickers 1SB304P6S
        Vickers 1SB354P3W12S377
        Vickers 1SE140F20S4
        Vickers 1SE140F30S6
        Vickers 1SE140F40S4
        Vickers 1SE30F20S10
        Vickers 1SE30F20S2
        Vickers 1SE30F20S2-SP50BAR
        Vickers 1SE30F20S2SP-80BAR
        Vickers 1SE30F20S5
        Vickers 1SE30F20S5SP-80
        Vickers 1SE30F35S10
        Vickers 1SE30F35S10-SP2400
        Vickers 1SE30F35S10-SP3500
        Vickers 1SE30F35S10-SP3600
        Vickers 1SE30F35S10-SP4500
        Vickers 1SE30F35S12-SP4500
        Vickers 1SE30F35S2
        Vickers 1SE30F35S2SP-130
        Vickers 1SE30F35S2-SP270BAR
        Vickers 1SE30F35S2-SP3500
        Vickers 1SE30F35S2-SP3700
        Vickers 1SE30F35S2-SP500 0
        Vickers 1SE30F35S5
        Vickers 1SE30F35S5-SP115BAR
        Vickers 1SE30F35S5-SP1800
        Vickers 1SE30F35S5-SP250BAR
        Vickers 1SE30F35S5SP-345
        Vickers 1SE30F35S5-SP4000
        Vickers 1SE30F7S10
        Vickers 1SE30N34.5S5
        Vickers 1SE30N35S10
        Vickers 1SE90F20S8-SP1500
        Vickers 1SE90F35S3
        Vickers 1SE90F35S4
        Vickers 1SE90F35S4-SP325 0
        Vickers 1SE90F35S4-SP4000
        Vickers 1SE90F35S6
        Vickers 1SE90F35S8
        Vickers 1SE90F35S8-SP4000
        Vickers 1SE90F35S8-SP500 0
        Vickers 1SE90N27.5S4
        Vickers 1SE90N28S4
        Vickers 1SEB30F10S5
        Vickers 1SEB30F35S5
        Vickers 1SEB30F35S5-SP3900
        Vickers 1SEB30F35S5-SP4000
        Vickers 1SEB30F35S5-SP4500
        Vickers 1SEB90-F-20S-4
        Vickers 1SEB90F35S4
        Vickers 1SEB90F35S4-SP3900
        Vickers 1SEB90F35S4-SP5000
        Vickers 1SEL140F20S160/6 0
        Vickers 1SEL140F30S
        Vickers 1SEL140F30S240/110
        Vickers 1SEL140-F-30S-290/50
        Vickers 1SEL140F40S290/60
        Vickers 1SEL140F40S300/50
        Vickers 1SEL30F20S
        Vickers 1SEL30F20S150/20
        Vickers 1SEL30-F-20S-150/60
        Vickers 1SEL30F20S200/70
        Vickers 1SEL30F20S-200/80
        Vickers 1SEL30F30S
        Vickers 1SEL30F30S220/50
        Vickers 1SEL30F30S-230/50
        Vickers 1SEL30F40S
        Vickers 1SEL30F40S300/50
        Vickers 1SEL30G40S
        Vickers 1SEL90F20S150/30
        Vickers 1SEL90F20S150/60
        Vickers 1SEL90F20S160/60
        Vickers 1SEL90F20S160/90
        Vickers 1SEL90F20S170/60
        Vickers 1SEL90F30S
        Vickers 1SEL90F30S220/60
        Vickers 1SEL90F30S230/120
        Vickers 1SEL90F30S230/60
        Vickers 1SEL90G30S240/60-HA
        Vickers 1SER140F30S4
        Vickers 1SER140F30S4-SP4100
        Vickers 1SER140F30S6
        Vickers 1SER30F20S4
        Vickers 1SER30F35S2
        Vickers 1SER30F35S4
        Vickers 1SER90F35S4
        Vickers 1SER90F35S6
        Vickers 1SH10
        Vickers 1SH20S
        Vickers 1SH20SV
        Vickers 1SH252WS377
        Vickers 1SH253WS377
        Vickers 1SH253WSV
        Vickers 1SH362WS
        Vickers 1T162W6S
        Vickers 1UAR100G7SV
        Vickers 1UAR100P20S
        Vickers 1UAR100P35S
        Vickers 1UAR100P35S-SP250BAR
        Vickers 1UAR100P35SV
        Vickers 1UAR100P7S
        Vickers 1UL255P6W4W20/35-S
        Vickers 1UL255P6W4W2028S
        Vickers 1UL60-G-35S
        Vickers 1UL60P10S
        Vickers 1UL60P10SV
        Vickers 1UL60P20S
        Vickers 1UL60P20S-90BAR
        Vickers 1UL60P20SV
        Vickers 1UL60P35S
        Vickers 1UL60P35S-200BAR
        Vickers 1UL60P35SV
        Vickers 1UL65P4W10S
        Vickers 1UL65P4W10S377
        Vickers 1UL65P4W20S
        Vickers 1UL65P4W35S
        Vickers 1UL65P4W35S377
        Vickers 1UPS100P20S
        Vickers 1UPS100P20SV
        Vickers 1UPS100P20SV-SP1700
        Vickers 1UPS100P35S
        Vickers 1VR100G20S
        Vickers 1VR100G35S
        Vickers 1VR100P20S
        Vickers 1VR100P20S-140BAR
        Vickers 1VR100P20S-150BAR
        Vickers 1VR100P20S-186BAR
        Vickers 1VR100P20S-200BAR
        Vickers 1VR100P20SV-210BAR
        Vickers 1VR100P35S
        Vickers 1VR100P35S-175BAR
        Vickers 1VR100P35S-225BAR
        Vickers 1VR100P35S-230BAR
        Vickers 1VR100P35S-280BAR
        Vickers 1VR100P35SSP-200BAR
        Vickers 1VR100P35SV
        Vickers 1VR100P35SV-210BAR
        Vickers 1VR100P35SV-240BAR
        Vickers 1VR100P35SV-250BAR
        Vickers 1VR100P35SV-SP242BAR
        Vickers 1VR100R20S
        Vickers 1VR150P6W20S
        Vickers 1VR150P6W35S
        Vickers 1VR200G35SV-230BAR
        Vickers 1VR200P20S
        Vickers 1VR200P20S-SP160BAR
        Vickers 1VR200P35S
        Vickers 1VR200P35SV
        Vickers 1VR200P35SVSP-200BAR
        Vickers 1VR200P35SV-SP36 0
        Vickers 1VR250P8W35S377
        Vickers 1VRC250P8W35S
        Vickers 1VRC250P8W35S377
        Vickers 2CFD150-100S
        Vickers 2CFD150-100SV
        Vickers 2CFD150-150S
        Vickers 2CFD150-150SV
        Vickers 2CFD1556W100S
        Vickers 2CFD1556W150S
        Vickers 2CFD200-150S
        Vickers 2CFD200-150SV
        Vickers 2CFD200-220S
        Vickers 2CFD200-220SV
        Vickers 2CFD200-95S
        Vickers 2CFD200-95SV
        Vickers 2CFD25010W8W150S
        Vickers 2CFD250-10W-8W-150S-377
        Vickers 2CFD2508W6W150S
        Vickers 2CFD2508W6W95/150SV
        Vickers 2CFD40-12S
        Vickers 2CFD40-22S
        Vickers 2CFD40-22SV
        Vickers 2CFD40-2S
        Vickers 2CFD40-40/50S
        Vickers 2CFD40-40S
        Vickers 2CFD40-50S
        Vickers 2CFD40-50SV
        Vickers 2CFD453W12S
        Vickers 2CFD454W3W12S
        Vickers 2CFD454W3W40S
        Vickers 2CFD454W3W40S377
        Vickers 2CFD454W3W50S377
        Vickers 2CFD50-10S
        Vickers 2CFD50-20/40S
        Vickers 2CFD50-20S
        Vickers 2CFD50-40S
        Vickers 2CFD50-40S-DO
        Vickers 2CFD50-5S
        Vickers 2CFD553W10S
        Vickers 2CFD553W20S
        Vickers 2CFD553W40S
        Vickers 2CFD553W5S
        Vickers 2CFD554W20S
        Vickers 2CFD554W3W40S
        Vickers 2CFD554W40S
        Vickers 2CFP60G4S
        Vickers 2CFP60G6S
        Vickers 2CFP60P4S
        Vickers 2CFP60P4S-10LPM
        Vickers 2CFP60P4S-20LPM
      在線詢盤/留言
    7. 0571-87774297  
      91精品国产综合久久婷婷