Technical details Connection G1/4, Namur Nominal size 6 mm Temperature range -10°C ... +70°C Medium Filtered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10°C below lowest occurring ambient temperature. Materials Body: Al (anodized), plastic, seals: NBR and POM, inner parts: Al, steel rostfrei and brass Protection IP 65 according to EN 60529 Valves in accordance with 2014/34/EU (ATEX) available. (page 7) 5/2- and 5/3-way-valves MN-06-510-HN-xxx 5/2-way, single solenoid, air spring return MN-06-511-HN-xxx 5/2-way, single solenoid, mechanical spring return MN-06-520-HN-xxx 5/2-way, double solenoid MN-06-530-HN-xxx 5/3-way, center position closed Electrical options Nominal voltage Power consumption Specifics Plug connection*1 -xxx 12 V DC 4.2 W Form B industrial norm -441 12 V DC 2.2 W max. 8 bar Form B industrial norm -461 24 V DC 4.2 W Form B industrial norm -442 24 V DC 4.2 W M 12 -O42 24 V DC 2.2 W max. 8 bar Form B industrial norm -462 24 V DC 2.5 W max. 8 bar M 12 -O62 24 V AC 7/4 VA Form B industrial norm -452 115 V AC 7/4 VA Form B industrial norm -456 230 V AC 7/4 VA Form B industrial norm -457 *1 Plug socket not included, suitable plug sockets see page 3. 14 4 2 5 1 3 14 4 2 5 1 3 14 4 2 12 5 1 3 4 2 5 1 3 14 12 02 Subject?to?change Valves > standardized valves > electrically operated > Series MN-06 NAMUR Model-no.: MN-06-310 MN-06-311 MN-06-510 MN-06-511 MN-06-520 MN-06-530 Operating pressure* (bar) 2...10 3...10 2...10 3...10 2...10 3...10 Pilot pressure* (bar) 2...10 3...10 2...10 3...10 2...10 3...10 Flow rate (Nl/min) 750 750 750 750 750 650 Response time (ms) at 6 bar on: 13 off: 16 on: 13 off: 16 on: 13 off: 16 on: 13 off: 16 on: 12 off: 12 on: 13 off: 15 Weight (kg) 0.320 0.320 0.320 0.320 0.460 0.460 * max. 8 bar at 2.2 W and 2.5 W Technical data Dimensions M-04-310-HN. MO-04-310-HN MN-06-31x-HN M-04-310-HN, MO-04-310-HN MN-06-51x-HN MN-06-520-HN, MN-06-530-HN 137 25 3 ? 5.5 128 3 1 45 32 70.5 1 = pressure inlet 2,4 = outlets 3,5 = exhausts 24 2 183 202 44 137 25 24 ? 5.5 128 5 1 45 32 70.5 22 22 3 4 2 Plug socket (not included in scope of delivery) can be repositioned by 180°. Solenoid coil can be repositioned by 4 x 90°