      • ABB sdcs-IOB-21
        發布者:廈門紀揚科技有限公司  發布時間:2024-05-07 10:30:29  訪問次數:63


        BCU Burner control unit
        370 Series 370
        Q Mains voltage 120 V AC, 50/60 Hz
        W Mains voltage 230 V AC, 50/60 Hz
        — Without ignition
        I1 Electronic ignition, single-pole
        I2 Electronic ignition, double-pole
        I3 Electronic ignition, double-pole with neutral conductor
        F Fan control
        E Valve control
        U0 Ionization control (continuous op.) or UV control (intermittent op. with UVS)
        U1 UV control (continuous operation with UVD 1)
        D1 DGmax. monitoring
        D3 Integrated tightness control
        B1 PROFIBUS DP interface
        -3 Three-point step control via PROFIBUS DP
        For controlling, igniting and monitoring industrial forced draught burners of unlimited
        capacity in intermittent or continuous operation (in conjunction with UV sensor UVS, only
        intermittent operation available) for applications pursuant to EN 676.
        It can be used for directly ignited forced draught burners or forced draught burners
        ignited with a gas pilot. Programmable via an optical interface and the PC software
        BCSoft, with optional quick start without pre-purge, display of the program status, unit
        parameters and flame signal, integrated Manual mode for manual burner start, BCU
        370..D3 with tightness control function, BCU 370..B1 with PROFIBUS DP interface,
        can be programmed according to customer requirements, EU certified, AGA, FM, CSA
        (USA, Canada) and EAC approved, UL listed.
        Designation Order no.
        Without ignition; DGmax. monitoring
        BCU 370WFEU0D1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88600015
        Without ignition; integrated tightness control
        BCU 370WFEU0D3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88600023
        Electronic ignition, single-pole*; DGmax. monitoring
        BCU 370WI1FEU0D1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88600001
        Electronic ignition, single-pole*; integrated tightness
        control
        BCU 370WI1FEU0D3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88600206
        Versions
        BCU 370..B1 with PROFIBUS DP interface,
        connection in the lower section of the housing . . . . . . . . . . . . . . . . surcharge
        BCU 370..B1-3 with three-point step control
        via PROFIBUS DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . surcharge
        * Note the cable length and ignition energy (cf. Technical Information)
        BCU 370 Technical
        Information
        BCU 370
        6 Electric flame monitoring and control units
        2-90
         
        Burner control units BCU 570
        Type code
        BCU Burner control unit
        570 Series 570
        Q Mains voltage 120 V AC, 50/60 Hz
        W Mains voltage 230 V AC, 50/60 Hz
        C0 No valve proving system
        C1 Valve proving system
        F1 Modulating with IC interface
        F2 Modulating with RBW interface