      • ABB SDCS-PIN-25
        發布者:廈門紀揚科技有限公司  發布時間:2024-05-07 10:26:56  訪問次數:49


        – Pre-purge
        – Tightness test or proof of closure function (optional)
        – Temperature monitoring (optional)
        – Fieldbus connection (optional)
        6 Electric flame monitoring and control units
        6 Electric flame
        monitoring and
        control units
        2-80
         
        Protective system control FCU 500
        Type code
        FCU Protective system control
        500 Series 500
        Q Mains voltage 120 V AC, 50/60 Hz
        W Mains voltage 230 V AC, 50/60 Hz
        C0 No valve proving system
        C1 Valve proving system
        F0 No capacity control
        F1 Modulating with IC interface
        F2 Modulating with RBW interface
        H0 No temperature monitoring
        H1 With temperature monitoring
        K0 No connection plugs
        K1 Connection plugs with screw terminals
        K2 Connection plugs with spring force terminals
        -E Individual packaging
        For monitoring and controlling central safety functions in multiple burner systems on
        industrial furnaces, checking of the valves and system for tightness using a valve proving
        system, safe recording of the furnace chamber temperature on high temperature equipment by a temperature monitor or temperature limiter, long service life due to replaceable load module for fail-safe outputs, can be programmed according to customer
        requirements, EU certified, FM and EAC approved, certified for systems up to SIL 3
        (compliant with PL e), FCU..H0: CSA approved.
        Designation Order no.
        For staged control
        FCU 500WC0F0H0K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621025
        For staged control, integrated valve proving system
        FCU 500WC1F0H0K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621026
        For modulating control using actuators IC
        FCU 500WC0F1H0K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621012
        For modulating control using actuators IC, integrated
        valve proving system
        FCU 500WC1F1H0K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621027
        For staged control, temperature monitoring
        FCU 500WC0F0H1K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621106
        For staged control, temperature monitoring, integrated
        valve proving system
        FCU 500WC1F0H1K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621092
        For modulating control using actuators IC, temperature
        monitoring
        FCU 500WC0F1H1K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621102
        For modulating control using actuators IC, temperature
        monitoring, integrated valve proving system
        FCU 500WC1F1H1K1-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88621103
        Versions
        FCU 500..K1 with connection plugs with screw terminals . . . . . . . surcharge
        FCU 500..K2 with connection plugs with spring force terminals . . surcharge
        Accessories for FCU 500
        Designation Order no.